In this content we explain lead-acid in to the 6 section as the following
- Construction - Now you're here
- Chemistry
- Battery Rating
- Dry Charged Batteries
- Battery Testing and Charging
- Battery Installation and Servicing
1.Construction of lead-acid battery.
1,1 Grid
Grid is framework for the active element in lead-acid battery formed by cast of alloy of lead and antimony.The open space of grids are filled with the active ingredient.
1.2 Negative Plates
Negative plates are grids which have their opening filled with a dull grey.mass spongy of porous lead.It have an expander mixed into it to prevent the losing of lead from the surface of plates.
1.3 Positive Plates
Positive Plates are grids which have their opening filled with a chocolate brown, a compound of lead peroxide with highly porous
1.4 Separators
Separator made from micro porous rubber. having vertical rib s next to the positive plate.This rib allows a greater volume of acid to be held in contact with positive plates and improve the efficiency of the cell and to retard the loss of lead peroxide after continued cycling.
1.5 Cell Element
Batteries always have one more negative .plate than the positive plates to protect the more active positive plates and prevent warpage by exposing both sides equally.All cell elements are connected with a connector strap welded onto each plate.
1.6 Container
Container of batteries are made by molding and can be classified into 2 types as
- Vented - without a separated box
- Unvented - connected with a rubber hose to an air scoop outside the airplane and go through the sump jar where they are neutralized.
1.7 Cell Connectors
Older batteries's are connected with a strap welded to the post up through the cell cover.
newer batteries are connected with a through-partition cell connector. This type provides a shorter path for the high current flow.
1.8 Cell Covers and Vents
A lead weight actuated valve allows the filler plug to vent when upright,but seals when tipped
1.9 Battery Terminals(Post)
Usually located on the top or the side,Side mounted terminal are usually fitted with a quick disconnect connector.
Note:The polarity,POS and NEG is normally molded into the cover in raised letters.
1.10 Electrolyte
This electrolyte are Sulfuric acid and water in a ratio of 65:35 (water:acid) by weight .This produces a specific gravity of about 1.265 at 80 degrees F.
Note: Electrolyte causes changes in positive and negative plates and in electrolyte itself.
End..
Next will be the Chemistry of lead-acid batteries. Click.